Spare parts spare parts, the DCS control system of PLC system and the robot system spare parts,
Brand advantage: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, machinery, electronics, automobile manufacturing, tobacco, plastics machinery, electric power, water conservancy, water treatment/environmental protection, municipal engineering, boiler heating, energy, power transmission and distribution and so on.
The local bus provides the connection between the individual electronics of the HACD family. You can use the local bus to configure another card connected to the local bus with the help of Bodac. However, never send firmware over the local bus to another electronics card to update the latter. You can connect up to 32 stations. A clear bus address must be assigned to each control electronics. The connection is established using a CAN protocol with a baud rate of 250 kbit. The maximum length of the most distant control electronics must not exceed 280 m. Moreover, the maximum length of the branch lines of 1 m must be observed. The data are transmitted over a shielded twisted-pair cable. For the setup, two bus terminal resistors of 120 Ohm are required.
▶ Lay solenoid cables of the proportional valve separately, away from other cables; in particular, they must be separated from cables of the inductive position transducers. We recommend the use of shielded solenoid cables. Recommended cable type: LiYCY 1.5 mm2 up to 50 m length. When double-shielded cable is used, the outer shield can be terminated at the entry into the control cabinet, the inner shield can be terminated at the control electronics.
Use a mating connector CECc 75301-803-A002FAH3008-G according to DIN EN 175 301-803 and ISO 4400 for connecting the solenoids. • Solenoid “a”, mating connector, color: gray, separate order stating material no. R901017010 • Solenoid “b”, mating connector, color: black, separate order stating material no. R901017011
The transducer is connected using a 4-pin mating connector Pg7-G5W1F, which can be ordered separately stating material no. R900023126. Up to a length of 50 m we recommend the use of 4 x 0.25 mm² connection cables of type LiYCYCY. When double shielded cable is used, the outer shield can be terminated at the entry into the control cabinet, the inner shield can be terminated at the control electronics. The shield needs only to be connected to pin z10 of the edge connector on the supply side.
The transducer is connected using a 4-pin mating connector Pg7-G5W1F, which must be ordered separately stating material no. R900023126. Up to a length of 50 m we recommend the use of a connection cable 4 x 0.25 mm² of type LiYCYCY. When double shielded cable is used, the outer shield can be terminated at the entry into the control cabinet, the inner shield can be terminated at the control electronics.
In conjunction with this pump type, the swivel angle transducer is installed oilimmersed. We recommend the use of cable type ÖLFLON® PTFE/FEP 4 x 0.25 mm² (by Lapp Kabel). When double shielded cable is used, the outer shield can be terminated at the entry into the control cabinet, the inner shield can be terminated at the control electronics.